TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 67 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
7 General operating instructions to set parameters
7.1 Open the parameter operation mode
1.
Turn off the door controller and wait until the display has been completely
extinguished.
2.
Open the cover of the enclosure and switch the DIP switch S1300 (see
illustration) to ON. The service mode is activated and you can close the cover.
Figure 41: DIP switch position
The service mode is automatically reset after approx. 1 hour. In order to reach service
mode again, the controller must be turned off for a short period and then turned on again
or a reset must be performed.
3.
Close the cover of the enclosure and turn on the controller.
4.
+
Keep the keys pressed simultaneously to access the
parameter selection.
P: Torzyklen |
000# 1234Zyk
5.
or
Use the arrow keys to select the required parameter.
Not all the parameters are visible or may be changed
immediately; this always depends on the password and
the type of position set.
P: Offenhalt 1 |
010= 10 s
SERVICE
S1300

Table of Contents