EasyManuals Logo

Feig Electronic TST FUF2 Series User Manual

Feig Electronic TST FUF2 Series
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
TST Assembly instructions FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH page 81 of 114 TST_FUxF-A-C-F_Montageanleitung_EN_15
12 Messages
12.1 Error messages
Faults can be acknowledged provided they are not reset automatically.
The cause of the fault must be resolved first before the corresponding message is acknowledged.
Alternatively the
the STOP button can also be kept pressed for approx. 5 seconds.
No.
Description
Possible reason for error
F.000
Door position too far up
• Too small a parameter value for upper emergency limit switch → increase
P.239
• Upper limit switch range (limit switch band) too small → increase P.233
• Mechanical brake defective or improperly set
F.005
Outside door position too far down
• Too small a parameter value for lower emergency limit switch → increase P.
229
• Lower limit switch range (limit switch band) too small → increase P. 223
• Mechanical brake defective or improperly set
F.020
Run time exceeded (during opening, closing or
deadman)
• Current motor run time has exceeded set maximum run time (P.410
(Opening), P.415 (Closing), P.419 (Deadman move)), door may be sticking or
is blocked.
• Door is blocked
• If using mechanical limit switches, one may not have tripped
F.021
Emergency opening wrong testing
• The max. allowed run time (P.490) during testing has exceeded
• Call service hotline
F.030
Lag error (position change of the door is less than
expected)
• door or motor is blocked
• insufficient power for providing necessary torque
• too little speed
mechanical limit switch was not left or is defective
• Incremental or absolute encoder shaft is slipping
• wrong positioning system selected (P.205)
• one motor phase is missing
• the brake does not release
• Settings of the failure detecting time are not correct (P.430 or P.450)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Feig Electronic TST FUF2 Series and is the answer not in the manual?

Feig Electronic TST FUF2 Series Specifications

General IconGeneral
BrandFeig Electronic
ModelTST FUF2 Series
CategoryController
LanguageEnglish

Related product manuals