Possible reason for error
Wrong Test of input 1 of the
mobile unit TST FSx
• Input 1 of the mobile unit was tested as faulty
• The device connected to the input does not work
• The mobile unit is defective
Wrong Test of input 2 of the
mobile unit TST FSx
• Input 2 of the mobile unit was tested wrong
• The device which is connected to the input does not work correctly
• The mobile unit is defective
Wrong Test of input 3 of the
mobile unit TST FSx
• Input 3 of the mobile unit was tested as faulty
• The device connected to the input does not work
• The mobile unit is defective
Wrong Test of input 4 of the
mobile unit TST FSx
• Input 4 of the mobile unit was tested as faulty
• The device connected to the input does not work
• The mobile unit is defective
Wrong Test of input A of the
stationary unit TST FSx
• Input A of the stationary unit was tested wrong
• The device which is connected to the input does not work correct
• The stationary unit is defective
Wrong Test of input B of the
stationary unit TST FSx
• Input B of the stationary unit was tested wrong
• The device which is connected to the input does not work correct
• The stationary unit is defective
Wrong Test of input C of the
stationary unit TST FSx
• Input C of the stationary unit was tested wrong
• The device which is connected to the input does not work correct
• The stationary unit is defective
Testing incorrect for output 1 of
the stationary unit
• Output 1 of the stationary unit was tested as faulty
• The cable between the stationary unit and the controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
Testing incorrect for output 2 of
stationary unit
• Output 2 of the stationary unit was tested incorrectly
• The cable between stationary unit and controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings for parameter P.5xF, P.47b or P.465
Testing incorrect for output 3 of
the stationary unit
• Output 3 of the stationary unit was tested incorrectly
• The cable between the stationary unit and the controller is damaged or not connected
• The stationary unit is defective
• Incorrect settings of parameter P.5xF, P.47b or P.465
Wrong parameter setting input
1 of mobile unit
• The device which is connected to input 1 of the mobile unit does not fit to the settings
• Check Parameter P.F1F
Wrong parameter setting input
2 of mobile unit
• The device which is connected to input 2 of the mobile unit does not fit to the settings
• Check Parameter P.F2F