Once the active parameter set has been changed, its parameterisation and teach-in data will be
provided for the operation of every Motion App subsequently started.
5 Technical appendix
5.1
Technical data
5.1.1 General
Characteristic valve values
Switching time on [ms] 8.5
Switching time off [ms] 8.5
C value [l/s*bar] 2
Standard nominal flow rate
Pressurisation
[l/min] 450
at 6 bar against 5 bar (0.6 MPa against 0.5 MPa)
Standard nominal flow rate
Exhaust
[l/min] 480
at 6 bar against 5 bar (0.6 MPa against 0.5 MPa)
Flow direction non-reversible
Tab. 126: Characteristic valve values
Pressure and medium parameters
Operating medium, control
medium
Compressed air in accordance with ISO 8573-1:2010
[7:4:4]
inert gases
Information on operating
medium, control medium
lubricated operation not possible
Vacuum operation only at the exhaust ports (3)
Valve terminal total leakage [l/h] 15 plus leakage of valve slots
Leakage per valve slot [l/h] 3 (with valve)
1 (with blind plate)
[bar] [MPa]
Nominal operating pres-
sure/nominal pilot pressure
6 0.6