EasyManua.ls Logo

Fimap MXR - Page 14

Fimap MXR
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-14
The vacuum motor doesn’t work properly
1 The vacuum motor is switched off Switch on the vacuum motor.
2 The vacuum motor is not powered
properly
Check the power connections on the
vacuum motor.
3 The microswitch on the squeegee
lifting lever doesn’t work
Replace the microswitch.
4 The display shows an alarm mes-
sage
Check what alarm message is
shown and solve the related issue
by following the proper instructions
(see section 5.6.1 at page 44).
5 The vacuum motor carbon brushes
are worn out
Replace the vacuum motor carbon
brushes.
6 The vacuum motor is supplied but
it doesn’t work
Replace the vacuum motor.
The squeegee doesn’t move
1 The squeegee Lever doesn’t move Check that there are no mechani-
cal obstacles to the movement of the
lever.
2 The lever moves but the squeegee
doesn’t move
Check that the lifting cable runs in
its sheath and the chain and the
rear lever is free to move.
3 The squeegee is lowered but it
doesn’t touch the ground
Check the settings of the lifting ca-
ble.

Table of Contents

Other manuals for Fimap MXR

Related product manuals