3-14
The vacuum motor doesn’t work properly
1 The vacuum motor is switched off ⇒ Switch on the vacuum motor.
2 The vacuum motor is not powered
properly
⇒ Check the power connections on the
vacuum motor.
3 The microswitch on the squeegee
lifting lever doesn’t work
⇒ Replace the microswitch.
4 The display shows an alarm mes-
sage
⇒ Check what alarm message is
shown and solve the related issue
by following the proper instructions
(see section 5.6.1 at page 44).
5 The vacuum motor carbon brushes
are worn out
⇒ Replace the vacuum motor carbon
brushes.
6 The vacuum motor is supplied but
it doesn’t work
⇒ Replace the vacuum motor.
The squeegee doesn’t move
1 The squeegee Lever doesn’t move ⇒ Check that there are no mechani-
cal obstacles to the movement of the
lever.
2 The lever moves but the squeegee
doesn’t move
⇒ Check that the lifting cable runs in
its sheath and the chain and the
rear lever is free to move.
3 The squeegee is lowered but it
doesn’t touch the ground
⇒ Check the settings of the lifting ca-
ble.