5-47
General Sets
MENU DEFAULT VALUES DESCRIPTION
General Sets:
Language: ##
IT IT-EN-FR-SP-
DE
Setup the language of the display.
General Sets:
Mod: ###
Mxr . . . Setup of the machine model (Normal version or with dosing
system).
General Sets:
Battery: ##
GEL GEL-WET-
AGM-GE1-
WE1
Setup of the battery type.
General Sets:
Rst.Cnthr: ##
N Reset partial hourmeter (like on “working menu”).
General Sets:
Rst.Main Cnthr: ##
N Reset total hourmeter (key, brush, vacuum, traction).
Brushes Sets
Parameter Default Min ÷ Max Description
Brushes Sets:
I Max: ## [Amp]
50 20 ÷ 80 Maximum current from the main card to the brush motor.
Brushes Sets:
I Nom: ## [Amp]
22 10 ÷ 40 Rated current; with T Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
T Nom: ## [s]
30 1 ÷ 60 Rated timer; with I Nom manages the amperometric protection
(alarm + stop brush motor).
Brushes Sets:
T Off: #.# [s]
0.2 0.0 ÷ 10.0 Delay of switching off of the brush motor when the safety lever is
released.
Brushes Sets:
T Reset: ## [s]
10 0 ÷ 100 Timing of reset amperometric protection (overcurrent).
Brushes Sets:
T On: #.# [s]
0.5 0.0 ÷ 5.0 Delay to switching on of the brush motor when the safety lever is
pressed.
Brushes Sets:
Eco Speed: ## [V]
17 15 ÷ 20 Value of Voltage reduction of brush motor, during ECO mode.
Brushes Sets:
Lev.1: ### [A]
15 5 ÷ 35 Parameter not managed.
Brushes Sets:
Lev.2: ### [A]
25 5 ÷ 35 Parameter not managed.
Brushes Sets:
Lev.3: ### [A]
35 5 ÷ 35 Parameter not managed.
Pumps Sets
Parameter not managed