26
CONTROL PANEL GUIDE AND SYSTEM OPERATION (CONTINUED)
START UP DISPLAY (CONTINUED)
If the controller
remains OFFLINE,
a fault code will be
generated and the
"FC" icon will appear
next to the fuel gauge
and flash repeatedly.
See the Fault Code
section of the manual
to address Fault
Codes.
Under normal
conditions, the
controller should come
ONLINE after five (5)
seconds. There should
be no Fault Codes.
The display will still
indicate that the radio
remote is still turned
off. At this point, the
controller is awaiting
a decision from the
operator on whether or
not the radio remote
will be used during
operation.
If machine interlock
errors are present
for the unit, they
will appear after the
controller is ONLINE.
The screen shown
here illustrates that
there are multiple
Emergency Stop
(E-Stop) buttons that
have been pushed. It
also shows that a door
on the unit is open or
not completely closed.
Before the engine can
be started, the E-Stops
must be released
and the door must be
closed completely.