Panda fpControl
Page 16 - Chapter 2: Panda fpControl 27.5.20
Fig. 2.3.1-3: Address PageThe CP-G then displays the address page for one second.
Fig. 2.3.1-4: Overview Page 1At the end of the power-on routine, the CP-G displays the
first overview page.
The language as well as the display mode can be set in the
menu.
Overview Page 1 is the same in all display modes/languages.
2.3.1.1 Overview page with Autostart activated
Warning! AutostartDeadly danger! - The generator can be equipped with an
Autostart function. This means that the generator is
started by an external signal. In order to prevent an
inadvertent start-up, the starter battery must be
disconnected before work on the generator may
commence.
The “Autostart” also remains active, if the fpControl
CP-G is switched off and on again.
If a fault should arise when the generator is started or is
already operating, it is stopped and the Autostart is set to
"off".
If the generator is operated by Autostart and is stopped
manually, the Autostart is set to "off".
Once the system has been switched off and then on again,
the Autostart is active once more.
Fig. 2.3.1-1: Overview Page 1 with AutostartThe first overview page shows if the Autostart is active.
Overview Page 1 with Autostart function activated.