Flashforge Corporation
Dreamer User Guide | www.flashforge.com
plate as (0, 0, 0). (NOTE: X, Y, and Z boxes are for display purposes. Changing the
value in the boxes will not affect anything.
f. Center X/Y/Z button: Extruder and build platform will back to the zero (0, 0, 0)
g. X/Y Speed and Z Speed: Set the move speed of extruder/ build platform.
● Limit Switch: In order to protect your Dreamer, three limit switches are equipped
to control the maximum position, and the three limit switches corresponding to X/Y/Z
axis limit switch. It has two statuses:
a. Not Trigger ed: If the extruder/build plate don’t move to its maximum, X/Y/Z axis
limit switch is not triggered, and shows “Not Tr igger ed”.
b. Tr igger ed: If the extruder/build plate moves to its maximum, X/Y/Z axis limit
switch is triggered, and shows “Tr igger ed”.
● Stepper Motor Controls: Allows users to control to stepper motor. Click [Enable],
and lock the motor so it does not allow any movement; click [Disable], and unlock
the motor to be controlled manually.
● LED Color : Allows users to change the LED color of Dreamer.
● Extruder Contr ols: You can set the value of “Motor Speed (RPM)”, which can
control the rotation speed of filament feeding wheel. The motor rotation time can be
controlled via setting the value of “Extruder Dur ation”. Generally we suggest the
users choose option of continuous time 60 seconds. The filament must be loaded in
the extruder before motor starts. Ther efor e, do not star t r otation oper ation until
the extr uder temperatur e r each the pr inting temper ature of filament. For PLA
filament, the extruder temperature should reach 220℃, after reaching the extruder
temperature, click the [Forwar d]/[Rever se] rotation button to control filament load
and filament unload. Furthermore, if you want to stop filament load and unload, you