EasyManua.ls Logo

FLENDER ARPEX - 6.10.4 Test Run of Fitted Dummies

FLENDER ARPEX
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
ARPEX 8706 en
Operating instructions 10/2017
Remove the dummy flange after the test run.
Undo the screw connection of the flange (see figure 41) between the fitted coupling part and the dummy
flange and remove the dummy flange.
If necessary, using the hexagonsocket closefitting bolts of the flange screw connection (see figure 41),
which must be screwed into the tapped holes provided for in the fitted coupling parts or into the dummy
flanges, press the dummy flange (see figure 41) out of the recess (centering pin) (see figure 42).
Fig. 42: Removing the flange connection dummy flange
WARNING
Risk of serious injury through flying fragments
Risk of serious injury through flying fragments and/or risk of damage to the coupling.
Secure all coupling parts before undoing the screw connection.
6.10.4 Test run of fitted dummies
Observe the safety instructions in section 6.1, "General information on fitting"!
Before starting fitting work the contact surfaces of the dummy and the shaft ends must be carefully cleaned
and all preservative agent must be removed. Specifications relating to pulling-on action can be found on
the orderspecific drawing of the coupling.
CAUTION
Risk of corrosion burns through chemical substances
Avoid burns when working with corrosive cleaning agents.
Observe manufacturer’s instructions for handling cleaning agents and solvents.
Wear suitable personal protective equipment (gloves, safety glasses).
12
Fig. 43: Fitting the dummy
1 Customer’s shaft 2 Dummy

Table of Contents

Related product manuals