50
ARPEX 8706 en
Operating instructions 10/2017
6.11.2 Procedure applying to modules with threaded bush
Observe the safety instructions in section 6.1, "General information on fitting"!
Reinsert the collar bolts of the fastening (see figure 48) again. The design of the fastening is shown on the
orderspecific drawing of the coupling. Make sure that the collar bolts are only inserted loosely without
being tightened.
Fig. 48: Inserting the collar bolts of the fastening
Undo the screw connection of the flange (see figs. 6 to 16) and remove them.
WARNING
Serious injury
Risk of serious injury through falling coupling parts and/or flying fragments and/or risk of damage to the
coupling.
Secure all coupling parts against falling before undoing the screw connection.
Tighten the collar bolts of the fastening as far as the coupling flanges will go (see figure 49), so that the plate
packs are clinched axially and the intermediate unit can be removed.
Fig. 49: Tightening the collar bolt
If necessary, also shift the shaft ends of the machines to be joined together axially.
If necessary, using the hexagonsocket fitting bolts of the flange screw connection (see figures 6 to 16),
which must be screwed into the tapped holes provided for in the coupling parts, press the intermediate unit
(see figs. 6 to 16) out of the recess (centering pin) (see figure 50).
Fig. 50: Demounting the flange connection