60
ARPEX 8706 en
Operating instructions 10/2017
9.3.2 Possible faults when fitting the coupling
Components with transport or other damage are being fitted.
When fitting coupling parts in a heated condition, these components are being excessively heated.
The shaft diameter is beyond the specified tolerance range.
Coupling parts are interchanged during fitting work.
Nonobservance of component markings for assembly balancing (see item 6.7) while the coupling is
fitted.
Specified tightening torques are not being adhered to.
Alignment and/or shaftmisalignment values do not match the specifications on the orderspecific
drawing of the coupling.
The coupling protection used is not suitable for operation within the meaning of the
explosionprotection requirements and/or in accordance with Directive 2014/34/EU.
Operating conditions are being changed without authorisation.
9.3.3 Possible faults in the maintenance of the plant
Maintenance intervals are not being adhered to.
Impermissible shaft misalignments occur, which are caused by the coupled units settling and were not
taken into consideration when designing the coupling.
Leakage in the vicinity of the coupling is not being identified and as a result chemically aggressive
media are damaging the coupling.