FLUXUS F70x 12 Data Logger and Transmission of Data
114 UMFLUXUS_F7V4-6-2EN, 2017-10-01
Start of the storing
If it is necessary to synchronize the storing of measured values on several transmitters, the starting time of the storing can
be set.
Acoustic signal during the storing
Per default, an acoustic signal will be emitted every time a measured value is stored or transmitted to a PC or printer. The
signal can be deactivated in Special Funct.\SYSTEM settings\Storing\Beep on storage.
12.1.4 Measurement with Activated Data Logger
Start the measurement.
If Output Options\Store Meas.Data has been activated and Special Funct.\SYSTEM settings\
Ringbuf-
fer is deactivated, this error message will be displayed as soon as the data logger is full.
The storing will be stopped.
12.1.5 Deleting the Measured Values
12.1.6 Available Data Logger Memory
If the data logger is empty and a measurement is started with one physical quantity on one measuring channel without
storing the totalizer, approx. 100 000 measured values can be stored. The available data logger memory can be dis-
played:
Select the starting time of the storing of measured values.
Promptly: Storing will be started immediately.
On full 5 min.: Storing will be started on the next full 5 minutes.
On full 10 min.: Storing will be started on the next full 10 minutes.
On quarter hour: Storing will be started on the next full 15 minutes.
On half hour: Storing will be started on the next half hour.
On full hour: Storing will be started on the next full hour.
Example: current time: 9:06
setting: On full 10 min.
Storing will be started at 9:10.
Select off to deactivate the acoustic signal, on to activate it. Press ENTER.
Enter the measuring point number. Press ENTER.
If arrows are displayed in the lower line on the right, ASCII text can be entered. If digits are
displayed, only digits, point and hyphen can be entered.
For the setting of the input mode see section 14.2.3.
Press ENTER.
The error message will be displayed periodically.
Select Special Funct.\Delete Meas.Val. Press ENTER.
Select yes or no. Press ENTER.
Select Special Funct.\Instrum. Inform.. Press ENTER.
The type and the serial number of the transmitter will be displayed in the upper line.
The available data logger memory will be displayed in the lower line (here: 18 327 addition-
al measured values can be stored). Press key BRK twice to return to the main menu.
Start logger
Promptly
Beep on storage
>on< off
A:Meas.Point No.:
xxx (↑↓← )
DATA MEMORY
OVERFLOW!
Special Funct.
Delete Meas.Val.
Really Delete?
no >YES<
Special Funct.
Instrum. Inform.
F70X -XXXXXXXX
Free: 18327

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS F705**-NN Series and is the answer not in the manual?

Flexim FLUXUS F705**-NN Series Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS F705**-NN Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals