Page #90 background image
90 UMFLUXUS_G6V4-2EN, 2011-03-29
FLUXUS G60x 13 Advanced Measuring Functions
Selection of the Totalizers for Storing
It is possible to store only the value of the totalizer that is currently displayed or one value
for each flow direction. Select Special Funct.\SYSTEM settings\Stor-
ing\Quantity Storage.
When the Measurement is Stopped
The behavior of the totalizers when the measurement is stopped or after a RESET of the
transmitter is set in Special Funct.\SYSTEM settings\Measuring\Quantity
recall.
Tab. 13.1: Keys for display of the totalizers
activation press key once during the measurement
deactivation press key three times during the measurement
display of the totalizer for
the positive flow direction
press key during the measurement
display of the totalizer for
the negative flow direction
press key during the measurement
reset of the
totalizers to zero
press key three times during measurement
This error message will be displayed if the totalizers of a
measuring channel used for measuring the flow velocity
are to be activated. The flow velocity can not be totalized.
Note! The totalizers can only be activated for the measuring channel
whose measured values are displayed at the moment.
Note! The pressing of a key will only influence the totalizers if the totalizer
is displayed in the upper line.
If one is selected, only the value of the totalizer that is cur-
rently displayed will be stored.
If both is selected, the values of the totalizers totalizer for
both flow directions will be stored.
Press ENTER.
If on is selected, the values of the totalizers will be stored
and used for the next measurement.
If off is selected, the totalizers will be reset to zero.
ON
O
OFF
O
$
Q +
-
O
ON
O
A:NO COUNTING !
3.5 m/s
Quantity Storage
one >BOTH<
Quantity recall
off >ON<

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Flexim FLUXUS G601 and is the answer not in the manual?

Flexim FLUXUS G601 Specifications

General IconGeneral
BrandFlexim
ModelFLUXUS G601
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals