9 Measurement
9.4 Display of measured values FLUXUS G801
2020-06-26, UMFLUXUS_G801V1-0EN
102
9.4.5 Transducer distance
The transducer distance can be displayed during the measurement by scrolling with .
The optimum transducer distance (here: 51.2 mm) will be displayed in parentheses, followed by the entered transducer
distance (here: 50.8 mm).
The optimum transducer distance might change during the measurement (e.g., due to temperature fluctuations).
A deviation from the optimum transducer distance (here: 0.4 mm) will be compensated internally.
R flow profile
information about the flow profile based on the Reynolds number
T fully turbulent flow profile
L fully laminar flow profile
transition range between laminar and turbulent flow
? unknown, cannot be calculated
F flow velocity
comparison of the measured flow velocity with the flow limits of the system
OK, the flow velocity is not within the critical range
the flow velocity is above the current limit
the flow velocity is below the current cut-off flow
0 the flow velocity is within the limit range of the measuring method
? unknown, cannot be measured
Fig. 9.4: Display of the transducer distance
Notice!
Never change the transducer distance during the measurement.
Tab. 9.5: Description of the status line
value explanation
L=(51.2) 50.8 mm
54.5 m3/h