6 Mounting
6.1 Transmitter FLUXUS G801
2020-06-26, UMFLUXUS_G801V1-0EN
26
6.1 Transmitter
6.1.1 Opening and closing the housing
The transmitter has a countersunk screw which has to be unscrewed before the housing can be opened. Use 2 strap
wrenches (not included in the delivery) to open and close the housing. After the installation, make sure that the housing
is closed correctly and that the countersunk screw is tightened.
Notice!
Do not use objects which may damage the housing gasket to open the housing.
Fig. 6.1: Transmitter and strap wrench
1 – housing cover
2 – cover plate
3 – countersunk screw
4 – strap wrench
1
2
3
4
4