FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 149 of 170
PLC Output to FT-112(D) Panel Input
Bitwise of a Dword:
Dword
(R/W)
B31
B30
B29
B28
B27
B26
B25
B24
B23
B22
B21
B20
B19
B18
B17
B16
B15
B14
B13
B12
B11
B10
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
1st
Dword
(OUTPUT)
(RWr0,
RWr1)
Next Dword defines the usage of this Dword.
2nd
Dword
(OUTPUT)
(RWr2,
RWr3)
Out
5
Out
4
Out
3
Out
2
Out
1
Expanded Commands List
Not in use
Command List
Read Data Selection
New
CMD
PLC Output to FT-112(D) Panel Input 2
nd
Dword
Bit Number
2
nd
Dword descriptions
B31… B24
Set / Reset digital outputs
B23… B16
Expanded Commands List (Refer to Table 15-3)
B15… B11
Not in use
B10 … B6
Command
List
Bin
Dec
Commands
00000
0
None command is activated
00001
1
Zero
00010
2
Tare
00011
3
Clear
00100
4
Print
00101
5
Adjust zero calibration
Calibration
00110
6
Adjust span calibration
(1)
00111
7
Total Load Cell Capacity
(1)
eCal
Coefficients
Refer to par. [613]
01000
8
Average mV/V value
(1)
01001
9
Dead Load value
(1)
01010
10
Save the coefficients of eCal
01011
11
CN (Label number)
(1)
01100
12
Preset Tare
(1)
01101
13
Grand Total
01110
14
Not used
01111
15
B. weighing
Filling
C.weighing
Classifying
Peak hold
SetPoint-1
Target
Target
Target
Follow
10000
16
SetPoint-2
Coarse
Low
--Low
Mid Decr.
10001
17
SetPoint-3
Fine
High
-Low
End Decr.
10010
18
SetPoint-4
TareMin
Empty
+High
Stop
10011
19
SetPoint-5
TareMa
x
Not used
++High
Alarm
10100
20
Not used
Empty
Not used
Empty
Empty
10101
21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-, page 61 to
see the availabilities.
10110
22
SetPoint-2 Low
10111
23
SetPoint-3 Low