EasyManua.ls Logo

Flintec FT-112 - Page 151

Flintec FT-112
170 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-112(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 150 of 170
11000
24
SetPoint-4 Low
11001
25
SetPoint-5 Low
11010
11110
26
30
Not used
11111
31
Use the Expanded Command list
(Refer to Table 15-3)
B5 ... B1
Read Data
Selection
00000
0
Actual weight (Net if the indication is in Net)
00001
1
Gross weight
00010
2
Tare weight
00011
3
ALL Status (Refer to Table 15-1)
00100
4
Calibration Status (Refer to Table 15-2)
00101
5
Last print value
00110
6
Quantity of M+
00111
01010
7
10
Not used
01011
11
CN (Label number)
01100
12
Totalization of M+
01101
13
Grand Total
01110
14
Not used
01111
15
B. weighing
Filling
C.weighing
Classifying
Peak hold
SetPoint-1
Target
Target
Target
Follow
10000
16
SetPoint-2
Coarse
Low
--Low
Mid Decr.
10001
17
SetPoint-3
Fine
High
-Low
End Decr.
10010
18
SetPoint-4
TareMin
Empty
+High
Stop
10011
19
SetPoint-5
TareMax
Not used
++High
Alarm
10100
20
Not used
Empty
Not used
Empty
Empty
10101
21
SetPoint-1 Low
Only available for Threshold and
Window feature.
Refer to sub-block 36-, page 61 to
see the availabilities.
10110
22
SetPoint-2 Low
10111
23
SetPoint-3 Low
11000
24
SetPoint-4 Low
11001
25
SetPoint-5 Low
11010
11110
26
30
Not used
11111
31
Use the Expanded Command list
(Refer to Table 15-3)
B0
New CMD
Toggle
Apply commands which are listed in this table.
(1) Write this command after writing values to 1
st
Dword, then apply this command with New CMD