Detector Type | Uncooled Microbolometer |
---|---|
Resolution | 320 x 240 pixels |
Accuracy | ± 2 °C or ± 2% of reading |
Focus | Manual |
Ingress Protection (IP) Rating | IP54 |
Field of View (FOV) | 24° x 18° |
Frame Rate | 30 Hz |
Display | 3.5" LCD touchscreen |
Operating Temperature Range | -15 °C to 50 °C |
Storage Temperature Range | -40°C to +70°C |
Covers warnings for digital devices, RF energy, and laser pointers.
Details precautions for handling, charging, and using camera batteries.
Provides warnings for operating conditions, liquids, and cleaning lenses.
Introduces the GF300 camera for OGI of VOCs, detailing its applications and benefits.
Introduces the GF304 camera for OGI of refrigerant gases, detailing applications and benefits.
Provides a step-by-step procedure for detecting temperature with the camera.
Offers a procedure to detect gas leaks using the camera.
Provides instructions on manually adjusting the camera's focus using the focus ring.
Explains how to adjust the camera focus using buttons.
Details image adjustment methods: Auto, HSM, and Manual.
Guides users on selecting appropriate temperature ranges for accurate measurements.
Details how to set object parameters like emissivity, distance, and atmosphere for accurate measurements.
Provides instructions for charging the camera battery using different methods.
Details the procedure for inserting and removing the camera battery.
Explains how to power on the camera, including the cooler warm-up process.
Describes the procedure for powering off the camera.
Provides steps for installing an infrared lens onto the camera.
Details the procedure for safely removing an infrared lens.
Guides on mounting the heatshield for high-temperature applications and entering transmission values.
Explains how to save images directly or preview and save them to an SD card.
Describes how to edit measurements, adjust images, or delete saved images.
Guides on placing measurement tools like spotmeters or boxes on the screen.
Explains how to reposition or change the size of measurement tools.
Details how to set up difference calculations between measurements or reference values.
Describes recording infrared or visual video clips and their compatibility with FLIR software.
Provides instructions on starting, stopping, and managing video clips.
Details the steps to navigate menus and change camera settings.
Explains setting up a peer-to-peer WLAN network for device connectivity.
Guides on setting up an infrastructure WLAN network for communication.
Details cleaning procedures for camera body, cables, and external items.
Provides instructions and precautions for cleaning the infrared lens.
Lists gases detectable by the FLIR GF300 with molecular and structural formulas.
Lists coolants detectable by the FLIR GF304.
Lists gases detectable by the FLIR GF306 with formulas.
Lists gases detectable by the FLIR GF320 with formulas.
Lists gases detectable by the FLIR GF346 with formulas.
Explains transitions and interactions allowing molecules to absorb/emit photons.
Discusses emissivity as a key parameter for accurate temperature measurement.
Explains compensation for radiation reflected by the object.
Explains the factors influencing radiation received by the camera.
Details the derivation of the general measurement formula used in FLIR equipment.
Presents emissivity values for various materials across different spectra and temperatures.