14 Technical specifications &
dimensional drawings
➲ FLIR Systems reserves the right to discontinue models, parts and accessories, and
other items, or change specifications at any time without prior notice.
14.1 Imaging performance
ManualFocus
Approx. 15 secondsStart-up time
< 1 second @ +25 °C (+77 °F)Start-up time from stand-by
Focal Plane Array (FPA), uncooled microbolometer
320 × 240 pixels
Detector type
7.5–13 μmSpectral range
14.2 Image presentation
2.5" color LCD, 16-bit colorsDisplay
Composite video CVBS (ITU-R BT.470 PAL/SMPTE
170M NTSC)
Video output
14.3 Temperature range
Temperature range is subject to customer config-
uration, and/or three-digit camera type number.
The three-digit camera type number is the three
first digits in the camera S/N.
Refer to the camera menu system to see available
temperature ranges.
Temperature range
± 2 °C / ± 3.6 °F or ± 2 % of readingAccuracy
14.4 Laser LocatIR
Class 2Classification
Semiconductor AlGaInP diode laser,
1 mW/635 nm (red)
Type
14