2. Tap to start Live Move. A hint screen prompting the positioning of the sensor and
reflector in any one of the four designated 4 positions (10:30, 1:30, 4:30 and 7:30 o'clock
position as viewed towards the sensor) appears.
3. Use and to place the displayed sensor at the desired 45° position. This pos-
ition corresponds to the actual angular position of the sensor and reflector on the shafts. Tap
to confirm position. A hint to select desired Live Move direction appears.
l
Tap to perform offset corrections in the 3 to 9 direction
l
Tap to perform offset corrections in the 0 to 6 direction
l
Tap to cancel Live Move
4. If the laser beam is centered, the Live Move screen appears.
108 Version:1.0