To proceed with soft foot measurement, tap . The next screen is shown.
Rotate the shafts to position the sensor and reflector at the correct angular position. Use the
on-screen needle [1] as guidance. The needle should rest on the green sector.
Manual entry
Manual values may be determined using feeler gauges. Four points around the bolt point are
measured with feeler gauges. The calculated values are then entered in the soft foot applic-
ation.
Manual values do not require use of either sensor or reflector.
Swipe the blue button to "Manual". Manual entries are signified by the finger icon on the dis-
play.
Tap any one of the four pulsating value fields then proceed to enter the soft foot value at the
respective machine foot. Use the onscreen keyboard.
Repeat the procedure for all four feet positions.
The tolerance smiley will determine whether the soft foot requires correction or not.