Live Move screen
Note
Machines are aligned by vertical movement which involves the addition or removal of
shims at the machine feet, and horizontal movement, where machines are shifted side-
ways.
If the alignment condition of the machines is within tolerance (indicated by
or )
then there is no need to align the machines.
It is recommended to perform vertical corrections first, since the horizontal condition is
easily affected when anchor bolts are loosened and shims inserted and/or removed,
whereas the vertical condition is less prone to being affected when horizontal moves are
performed.
Check soft foot before you proceed.
Live Move is monitored in either the horizontal (H) or vertical (V) plane.
While in the results screen tap to prompt Live Move. A hint to select desired Live Move
plane appears.
l
Tap
to shim
l
Tap
to move machine sideways
l
Tap to cancel Live Move
If Active Clock is the measurement mode used, the next screen appears.