EasyManua.ls Logo

Fluke 831 - Taking Measurement Points Automatically

Fluke 831
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
l
(1) Vertical feet position (bold colored tolerance arrows show direction to move/correct
machine feet)
l
(2) Horizontal feet position (bold colored tolerance arrows show direction to move/-
correct machine feet)
l
(3) Vertical coupling results
l
(4) Horizontal coupling results
l
(5) Selected results mode
l
(6) Alignment condition tolerance icon
l
(7) Used to select Horizontal and Vertical feet and coupling results in 3D / 2D
l
(8) Save asset measurement results
l
(9) Create asset measurement result report
l
(10) Show asset measurement table
l
(11) Tap to start Live Move
Taking measurement points automatically
Measurement points may be taken automatically if the default setting item "Take points auto-
matically after stabilization" has been activated. The item 'Default settings' is found under
"Configuration".
The initial measurement is taken by tapping either the pulsating M or after sta-
bilization.
When the rotational angle of the sensor and reflector is within the sector range, a series of dots
in circular motion (1) indicate the stabilization process. Once this occurs stop the rotation of
the shafts and wait for the pulsating M to appear.
Fluke
831 61