RPM metric (mm) imperial (mils)
Acceptable Excellent Acceptable Excellent
Short flexible coup-
lings
Gap (per 100 mm or 10"
diameter)
600 0.15 0.10 14.9 10.0
750 0.12 0.08 12.3 8.2
900 0.10 0.07 10.5 7.0
1000 0.10 0.06 9.6 6.4
1200 0.08 0.05 8.2 5.4
1500 0.07 0.04 6.7 4.5
1800 0.06 0.04 5.7 3.8
3000 0.04 0.02 3.7 2.5
3600 0.03 0.02 3.1 2.1
6000 0.02 0.01 2.0 1.3
7200 0.02 0.01 1.7 1.1
Offset 600 0.23 0.13 9.0 5.1
750 0.18 0.10 7.3 4.1
900 0.16 0.09 6.1 3.4
1000 0.14 0.08 5.5 3.1
1200 0.12 0.07 4.6 2.6
1500 0.09 0.05 3.7 2.1
1800 0.08 0.04 3.1 1.8
3000 0.05 0.03 1.9 1.1
3600 0.04 0.02 1.6 0.9
6000 0.02 0.01 1.0 0.6
7200 0.02 0.01 0.8 0.5