Note
After measurement point is taken, the displayed sensor and reflector move to the next
clock position on the display.
If shaft rotation restrictions hinder measurements at particular shaft positions to be
taken, use or and bypass the positions.
Measurements must be taken in at least three positions over 90°, but more measurements
over a wider angle is recommended.
l
(1) Rotational arc shows rotational angle covered by the shafts during measurement.
The color of the arc sectors shows the attained measurement quality (4).
l
(2) Rotational angle completed by the shafts for current measurement
l
(3) Number of measurement points taken for current measurement
l
(4) Measurement quality for current measurement
l
(5) Results icon tap to view results.
64 Version:1.0