Getting Started with CableManager Software
Viewing Plots of DSP-4100 Test Results
B
B-9
Viewing Plots of DSP-4100 Test Results
If STORE PLOT DATA was enabled during an Autotest on a DSP-4100, the Plot
function is available for the uploaded results.
To see a plot for all the cable pairs, select a frequency-dependent test in the lower
half of the CableManager window; then click the
Plot button.
To see a plot for one cable pair, double-click on the pair in the list to the left of the
Plot button.
The plot includes a cursor readout that shows the measurement, frequency, limit,
and margin for the crosshair cursor on the plot. You can use the cursor to read the
values at any point on the plot as follows:
To move the cursor, click on the plot, then slide the mouse from side to side or
use the left and right arrow keys on the keyboard. Click again to freeze the
cursor.
Note
The cursor readout does not show a limit or margin for frequencies
that are beyond the test standard’s specifications.
To switch the cursor to a different pair, click on a cable pair listed near the
lower right side of the plot, or use the up and down arrow keys on the
keyboard. You can add or remove pairs from the plot by using the
Pairs menu.
To move the cursor to the worst margin or worst pair, use the Find menu.