Section II - Operations
MN06065 Rev. 0.3 (8/97) 7
Note: Any additive output that has a zero entry programmed in its
corresponding program code will always be disabled and will not
appear in the selection process.
Note: Additives selected manually will override the additives that are
programmed in the recipe that is being loaded.
8.
Once the driver or operator verifies that the addi-
tives that have been selected and are displayed
in step 4 are correct press "ENTER". The display
will light up momentarily and then go to the pre-
set display.
Midgrade P Gal
When the additives are selected the loading process
is the same as previously described.
Standby Mode
When the AccuLoad II is in the Standby Mode of op-
eration, the additive selection can be programmed to
be either automatically or manually selected, de-
pending on how the unit is programmed. The follow-
ing program codes in the Systems Directory must be
programmed correctly for additive selection in the
Standby Mode.
Communications EIA - 232
Code Description
701
EIA - 232 Communication Type must be pro-
grammed to either:
One EIA Type Terminal.
Two EIA Type Minicomputer.
702
EIA - 232 Communication Control must be
programmed to either:
Two Poll and Authorize.
Three Remote Control.
Note: If programmed two (Poll and Authorize) the additive will be
selected for each transaction. If programmed three (Remote Control)
the additive will be selected for each batch.
742
Communications Time-out must have a value
other than "000" programmed into it.
743
Communications Alarm Mode must be
programmed to either:
Zero Standby Mode.
Two Standby and Communication Alarm.
804
Manual/Auto Additive Injection option must
be programmed to either:
Zero for auto injectors where the additives
that are programmed in the AccuLoad II will
automatically be selected for each batch.
One for manual injectors at the beginning of
each transaction or batch depending on how
code 702 is programmed.
Communications EIA - 485
Code Description
705
EIA - 485 Communication Type must be
programmed to either:
One EIA Type Terminal.
Two EIA Type Minicomputer.
706
EIA - 485 Communication Control must be
programmed to either:
Two Poll and Authorize.
Three Remote Control.
Note: If programmed two (Poll and Authorize) the additive will be
selected for each transaction. If programmed three (Remote Control)
the additive will be selected for each batch.
742
Communications Time-out must have a value
other than "000" programmed into it.
743
Communications Alarm Mode must be pro-
grammed to either: