EasyManua.ls Logo

FMC Technologies Smith Meter AccuLoad II

FMC Technologies Smith Meter AccuLoad II
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section III - Dynamic Displays
MN06065 Rev. 0.3 (8/97) 23
Dynamic Display Reference (Batch)
00 - Product Delivered
The product delivered for the batch requested will be
displayed.
Recipe 01 Midgrade
01 - Raw Batch Volume
The raw total for the recipe requested for that batch
will be displayed.
Raw Batch 1000.22
02 - Gross Batch Volume
The gross total for the recipe requested for that
batch will be displayed.
Grs Batch 1000.22
03 - Gross at Standard Temperature Batch
Volume
The gross at standard temperature batch total for
the recipe requested for that batch will be displayed.
Gst Batch 0.00
04 - Net Batch Volume
The net total for the recipe requested for that batch
will be displayed.
Net Batch 0.00
05 - Mass Batch Totals
The mass total for the recipe requested for that
batch will be displayed.
Mass Batch 3244.98
06 - Raw Batch Volume (Product 1)
The raw total for product 1 of the recipe requested
for that batch will be displayed.
Regular Raw 499.97
Regular is the programmed name for product 1.
07 - Gross Batch Volume (Product 1)
The gross total for product 1 of the recipe requested
for that batch will be displayed.
Regular Grs 499.97
08 - Gross at Standard Temperature Batch
Volume (Product 1)
The gross at standard temperature total for product
1 of the recipe requested for that batch will be dis-
played.
Regular Gst 499.95
09 - Net Batch Volume (Product 1)
The net total for product 1 of the recipe requested
for that batch will be displayed.
Regular Net 0.00

Table of Contents