Section III - Dynamic Displays
MN06065 Rev. 0.3 (8/97) 17
09 - Injector #5 Volume
The additive injector #5 non-resettable totals will be
displayed.
Add 5 = 000005850 Oz
10 - Injector #6 Volume
The additive injector #6 non-resettable totals will be
displayed.
Add 6 = 000006120 Oz
11 - Injector #7 Volume
The additive injector #7 non-resettable totals will be
displayed.
Add 7 = 000008225 Oz
12 - Injector #8 Volume
The additive injector #8 non-resettable totals will be
displayed.
Add 8 = 000006720 Oz
13 - Injector #1 Pulse Rate (Units/Injection)
The additive injector #1 pulse rate will be displayed.
Inj1 Prg 40 Cal 39.20
Note:
The first number (40) indicates the programmed value. The
second number indicates the recalculated value. (This applies to
dynamic displays 13-20).
14 - Injector #2 Pulse Rate (Units/Injection)
The additive injector #2 pulse rate will be displayed.
Inj2 Prg 50 Cal 49.00
15 - Injector #3 Pulse Rate (Units/Injection)
The additive injector #3 pulse rate will be displayed.
Inj3 Prg 40 Cal 39.20
16 - Injector #4 Pulse Rate (Units/Injection)
The additive injector #4 pulse rate will be displayed.
Inj4 prg 50 Cal 49.00
17 - Injector #5 Pulse Rate (Units/Injection)
The additive injector #5 pulse rate will be displayed.
Inj5 Prg 0 Cal 0.00
18 - Injector #6 Pulse Rate (Units/Injection)
The additive injector #6 pulse rate will be displayed.
Inj6 Prg 0 Cal 0.00
19 - Injector #7 Pulse Rate (Units/Injection)
The additive injector #7 pulse rate will be displayed.
Inj7 Prg 0 Cal 0.00
20 - Injector #8 Pulse Rate (Units/Injection)
The additive injector #8 pulse rate will be displayed.
Inj8 Prg 0 Cal 0.00
21 - Last Power Failure
The last time the AccuLoad II experienced a power
failure will be displayed.
PF: 3:04:36 PM 11-08-89