3.8 trouble shooting
Trouble Possible Problem Solution
No power to Pro
Pak’r machine
Power cord unplugged
Power switch OFF
Toggle switch OFF
Fuse is blown
Display cover open
Plug power cord into Pro Pakr and outlet
Turn power switch ON
Turn toggle switch ON
Replace Fuse on power inlet
Tighten display cover screw with screwdriver
Film won’t run Film roll installed back-
wards
Non-FPI lm installed
No RFID signal
Turn lm roll around
Install FPI lm roll
Turn roll, if not responding contact FPI for as-
sistance
Cushions are at,
do not hold air
Air ll tube not inside lm
Air pump not working
Seals leaking
Too much air ll
Reload lm onto ll tube
Contact FPI for assistance
Adjust seal temperature or clean backingwheel
Reduce air ll
Film jams fre-
quently
Blade is dull
Backing wheel are worn
Fill tube is worn
Cone tip is worn
Replace / reverse / or slide the blade.
Replace or clean backingwheel.
Replace ll tube.
Replace cone tip
Machine stops
automatically
Jam sensor not responding
Length Control set to
continuous
Contact FPI for assistance
adjust length control. See page 20.