Installation Manual
4 COUNTRY SETTINGS
“Country settings” is a section of the app dedicated to the settings of functionalities for specic
countrieslike“Unbalancedload”or“RandomDelay”.Readbelowthespecicationsforeachfunction.
4.1 Unbalanced load
“Unbalancedload”detectionisaspecicfunctionforpowermanagement.According
torelevantstandardsforspeciccountries,thecurrentimbalancebetweenthe
phasesmust not dier by morethan a xedvalue(dierentfor each country).
This function avoids single-phase on board chargers to withdraw an unbalanced
currentfromthegridhigherthanspeciedbylocalregulations.
Thiscongurationismandatoryinthefollowingcountries:
• Germany
• Austria
• Switzerland
• Netherlands
The function is disabled by default. To activate it, click “Country Settings” on the
PowerUp homepage and select “Unbalanced load settings”. Open the drop-down
menu and select the current value according to the maximum allowable current
imbalance between the phases.
This value is 20 A for Germany and 16 A for Austria, Switzerland and Netherlands.
NOTICE
Once the function is enabled, to make the changes eective, always
restart the wallbox through the dedicated button in the homepage.