13 PB
SPECIFICATIONS
Product Specications (Indoor Unit)
Indoor model 24K 36K 48K 60K
NOTE:
1. Test Conditions:
1.1 Rated Capacity Test Conditions:
Cooling: Indoor: DB 80.0˚F /WB 67.0˚F Outdoor: DB 95.0˚F /WB 75.0˚F
Heating: Indoor: DB 70.0˚F /WB 60.0˚F Outdoor: DB 47˚F/WB 43˚F
1.2 SEER & HSPF Test Standard: AHRI 210/240.
2. The Sound Pressure Level is based on the following conditions:
Indoor Unit
Air Handler Unit
Measure the noise value of the point 3.28 feet in front of the outlet of the wind
tunnel and 3.28 feet high from the bottom of the unit.
3. The above data was measured in an anechoic chamber. Please take into consideration
the reflected sound of your specific application environment.
4. All specifications are subject to change by the manufacturer without prior notice.
5. Max. Running Current (A): REFER TO NAMEPLATE
6. Follow local and National electrical codes and regulations when selecting field wires, and all the above are the minimum wire
size.
2. When transmitting (SI) cable is longer than 100 feet, a larger wire size should be selected.
3. Install main switch and circuit breaker for each system separately. Select a high response type circuit breaker that acts within
0.1 second.
4. If an auxiliary heater is required and already installed on indoor unit, power source cable should be installed separately and the
size should be selected in accordance with Local and National Electrical Codes. Refer to Figure 203(Electric Heater Kit Selection
Table) for Specifications.
Figure 202