SPECIFICATIONS
Product Specications (Outdoor Unit)
Figure 201
Outdoor model 24K 36K 48K 60K
Power supply V/ph/Hz 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60
Cooling
Capacity Btu/h 22000 34000 48000 56000
Capacity(min‑
max)
Btu/h 6700‑26000 11800‑36800 18300‑52000 18300‑59400
Capacity(min‑
max)
W 2227‑7327 2814‑10697 5363‑15240 5363‑17409
Input W 2180 3370 4750 6780
Current A 10.0 15.4 21.8 31.0
EER2 W/W 2.96 2.96 2.96 2.42
SEER2 Btu/(W.h) 16.5 18.0 17.5 17.0
EER2 Btu/(W.h) 10.10 10.10 10.10 8.25
Heating
Capacity Btu/h 23000 35000 47000 56000
Capacity(min‑
max)
Btu/h 6700‑26000 8900‑38200 17600‑52000 17600‑56600
Capacity
heating(Rated)
@ 47°F
Btu/h 23000 35000 47000 56000
Capacity
heating(Rated)
@ 17°F"
Btu/h 15000 24000 31000 40000
Maximum
Heating
Capacity@ 5F
Btu/h 16100 24600 33000 34000
COP @
5F (Under
Maximum
Capacity)
W/W 2.10 2.10 1.90 1.86
Input W 1980 2950 4170 5290
Current A 9.5 14.1 19.5 21.0
HSPF2 Btu/(W.h) 9.0 9.5 8.5 8.5
COP2 W/W 3.4 3.5 3.3 3.1
COP2 Btu/(W.h) 11.60 11.94 11. 26 10.58
Min. Ampacity A 15 23 35 35
Max. td fuse/ breaker A 25 35 50 50
Communication cable (SI Cord) No. × AWG 5×18 5×18 5×18 5×18
Working Voltage 198V ~ 253V
Voltage Imbalance Within a 3% deviation from each voltage at the main terminal of outdoor unit.
Starting Voltage Higher than 85% of the Rated Voltage
Outdoor fan
motor
Type DC DC DC DC
Model
ZWK511A805001
SIC‑
71FW‑F8121‑1
SIC‑
71FW‑D8121‑1/
SIC‑
71FW‑D8121‑2
SIC‑
71FW‑D8121‑1/
SIC‑
71FW‑D8121‑2
Qty 1 1 2 2
Output W 60 121 121 121
Speed (Hi) r/min 880 810 850 850