29 PB
5.CAPACITIES AND SELECTION DATA
Performance data (Cooling operation at rated frequency)
36K outdoor unit matches 30K indoor unit
Airflow
(CMF)
Outdoor
DB
IWB (°F) 59 63 67 71
IDB (°F)
70 5 80
7 57 85 70 880 85 7775 80 7 57 5 80 85
800
5
TC
23.3 23.5 24.0 24.3 24.0 24.3 24.5 24.8 25.6 25.9 26.1 26.3 \ 31.3 31.5 31.7
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.30 1.32 1.33 1.33 1.33 1.34 1.35 1.37 1.37 1.38 1.39 1.41 \ 1.72 1.74 1.77
30
TC
24.3 24.5 25.0 25.4 25.0 25.4 25.6 25.9 26.8 27.0 27.3 27.4 \ 32.6 32.9 33.1
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.45 1.46 1.47 1.47 1.47 1.49 1.50 1.52 1.52 1.53 1.55 1.57 \ 1.92 1.93 1.96
65
TC
25.6 25.8 26.3 26.7 26.3 26.7 27.0 27.2 28.2 28.4 28.7 28.9 \ 34.3 34.6 34.9
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.61 1.63 1.64 1.64 1.64 1.66 1.67 1.69 1.69 1.70 1.72 1.74 \ 2.13 2.15 2.18
75
TC
25.6 25.9 26.4 26.7 26.4 26.7 27.0 27.3 28.3 28.5 28.8 29.0 \ 34.0 34.3 34.5
S/T
1.00 1.00 0.99 1.00 0.62 0.83 1.00 1.00 0.39 0.56 0.73 0.90 \ 0.39 0.53 0.67
kW
1.78 1.80 1.83 1.83 1.83 1.85 1.87 1.88 1.87 1.90 1.92 1.94 \ 2.35 2.37 2.39
85
TC
25.2 25.5 26.0 26.3 26.0 26.3 26.6 26.9 27.8 28.1 28.3 28.5 \ 33.4 33.7 33.8
S/T
1.00 1.00 1.00 1.00 0.62 0.84 1.00 1.00 0.39 0.57 0.74 0.91 \ 0.39 0.53 0.67
kW
2.01 2.03 2.06 2.06 2.06 2.08 2.10 2.12 2.12 2.14 2.16 2.18 \ 2.66 2.69 2.71
95
TC
24.8 25.0 25.6 25.9 25.6 25.9 26.2 26.4 27.4 27.7
27.8 28.1 \ 32.6 32.9 33.0
S/T
1.00 1.00 1.00 1.00 0.62 0.84 1.00 1.00 0.39 0.57
0.74 0.92 \ 0.39 0.53 0.68
kW
2.42 2.44 2.47 2.47 2.47 2.49 2.52 2.55 2.56 2.58
2.60 2.63 \ 3.17 3.19 3.22
105
TC
24.3 24.6 25.1 25.4 25.1 25.4 25.7 25.9 26.9 27.1 27.3 27.5 \ 31.5 31.6 31.7
S/T
0.99 1.00 1.00 1.00 0.62 0.84 1.00 1.00 0.39 0.57 0.75 0.93 \ 0.39 0.54 0.69
kW
2.88 2.91 2.94 2.94 2.94 2.97 3.00 3.04 3.04 3.07 3.09 3.12 \ 3.67 3.68 3.69
115
TC
21.7 22.0 22.5 22.7 22.5 22.7 23.0 23.2 24.2 24.3 24.4 24.6 \ 26.2 26.3 26.4
S/T
1.00 1.00 1.00 1.00 0.62 0.85 1.00 1.00 0.40 0.60 0.79 0.99 \ 0.39 0.58 0.76
kW
2.93 2.96 2.99 2.99 2.99 3.04 3.07 3.10 3.12 3.14 3.16 3.17 \ 3.27 3.29 3.30
122
TC
18.5 18.7 19.1 19.3 19.1 19.3 19.5 19.7 20.5 20.7 20.8 20.9 \ 22.2 22.4 22.5
S/T
1.00 1.00 1.00 1.00 0.62 0.85 1.00 1.00 0.40 0.60 0.79 0.99 \ 0.39 0.58 0.76
kW
3.02 3.05 3.08 3.08 3.08 3.13 3.16 3.19 3.21 3.23 3.26 3.27 \ 3.36 3.38 3.40
1000
5
TC
25.0 25.2 25.9 26.1 25.9 26.1 26.4 26.7 27.7 27.9 28.1 28.3 \ 33.4 33.6 33.9
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.52 1.54 1.55 1.55 1.55 1.57 1.59 1.61 1.60 1.62 1.64 1.66 \ 1.98 2.00 2.02
30
TC
26.1 26.4 27.0 27.3 27.0 27.3 27.6 27.8 28.9 29.1 29.3 29.6 \ 34.9 35.1 35.4
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.69 1.71 1.73 1.73 1.73 1.75 1.77 1.78 1.77 1.80 1.82 1.84 \ 2.20 2.23 2.24
65
TC
27.5 27.7 28.4 28.7 28.4 28.7 29.0 29.3 30.4 30.6 30.9 31.1 \ 36.7 37.0 37.2
S/T
0.99 1.00 1.00 1.00 0.63 0.86 1.00 1.00 0.39 0.58 0.76 0.94 \ 0.39 0.54 0.69
kW
1.88 1.90 1.92 1.92 1.92 1.94 1.96 1.98 1.97 2.00 2.02 2.04 \ 2.44 2.47 2.49
75
TC
27.5 27.8 28.4 28.7 28.4 28.7 29.0 29.4 30.4 30.7 30.9 31.1 \ 36.4 36.7 37.0
S/T
1.00 1.00 1.00 1.00 0.62 0.85 1.00 1.00 0.39 0.58 0.76 0.94 \ 0.39 0.54 0.69
kW
2.06 2.08 2.10 2.10 2.10 2.12 2.14 2.16 2.16 2.18 2.21 2.23 \ 2.57 2.60 2.62
85
TC
27.0 27.3 27.9 28.3 27.9 28.3 28.5 28.9 29.9 30.2 30.3 30.6 \ 35.5 35.7 36.0
S/T
1.00 1.00 1.00 1.00 0.63 0.86 1.00 1.00 0.39 0.58 0.76 0.95 \ 0.39 0.54 0.70
kW
2.26 2.28 2.32 2.32 2.32 2.34 2.36 2.39 2.39 2.41 2.43 2.46 \ 2.96 2.98 3.01
95
TC
26.7 27.0 27.7 27.9 27.7 27.9 28.2 28.5 29.3 29.7 30.0 30.2 \ 34.6 34.8 35.0
S/T
1.00 1.00 0.99 1.00 0.63 0.87 1.00 1.00 0.39 0.58 0.76 1.00 \ 0.39 0.55 0.71
kW
2.69 2.72 2.75 2.75 2.75 2.77 2.81 2.84 2.85 2.87 2.90 2.92 \ 3.48 3.52 3.54
105
TC
26.0 26.3 27.0 27.2 27.0 27.2 27.5 27.8 28.7 29.0 29.2 29.5 \ 32.1 32.1 32.3
S/T
0.99 1.00 0.99 1.00 0.63 0.87 1.00 1.00 0.39 0.59 0.78 1.00 \ 0.39 0.57 0.74
kW
3.18 3.21 3.24 3.24 3.24 3.29 3.32 3.35 3.36 3.39 3.42 3.44 \ 3.77 3.74 3.77
115
TC
21.6 21.8 22.3 22.5 22.3 22.5 22.8 23.0 24.5 24.6 24.3 24.3 \ 25.3 25.4 25.5
S/T
1.00 1.00 1.00 1.00 0.64 0.88 1.00 1.00 0.40 0.62 0.86 1.00 \ 0.40 0.62 0.84
kW
2.98 3.01 3.05 3.05 3.05 3.08 3.11 3.14 3.19 3.21 3.20 3.22 \ 3.25 3.27 3.28
122
TC
18.3 18.6 18.9 19.1 18.9 19.1 19.4 19.6 20.8 20.9 20.6 20.7 \ 21.5 21.6 21.7
S/T
1.00 1.00 1.00 1.00 0.62 0.85 1.00 1.00 0.40 0.60 0.79 0.99 \ 0.39 0.58 0.76
kW
3.07 3.11 3.14 3.14 3.14 3.17 3.20 3.23 3.29 3.31 3.30 3.32 \ 3.35 3.36 3.37
75
70
85
70
SPECIFICATIONS
Capacities and Selection Data frequency