30 PB
5.CAPACITIES AND SELECTION DATA
Airflow
(CMF)
Outdoor
DB
IWB (°F) 59 63 67 71
IDB (°F)
70 80
75 5 8
1200
5
TC
26.6 26.9 27.5 27.8 27.5 27.8 28.1 28.4 29.4 29.7 29.8 30.1 \ 35.2 35.5 36.0
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.78 1.80 1.82 1.82 1.82 1.84 1.86 1.88 1.88 1.89 1.92 1.93 \ 2.26 2.28 2.16
30
TC
27.8 28.1 28.7 29.0 28.7 29.0 29.3 29.7 30.7 31.0 31.1 31.4 \ 36.8 37.0 37.6
S/T
0.99 1.00 1.00 1.00 0.61 0.83 1.00 1.00 0.39 0.57 0.73 0.90 \ 0.39 0.53 0.67
kW
1.98 2.00 2.02 2.02 2.02 2.05 2.07 2.08 2.08 2.10 2.13 2.15 \ 2.52 2.53 2.40
65
TC
29.2 29.6 30.2 30.5 30.2 30.5 30.9 31.2 32.3 32.6 32.8 33.0 \ 38.7 39.0 39.6
S/T
0.99 1.00 1.00 1.00 0.64 0.88 1.00 1.00 0.39 0.59 0.78 0.99 \ 0.38 0.55 0.71
kW
2.20 2.22 2.24 2.24 2.24 2.27 2.29 2.32 2.32 2.34 2.37 2.39 \ 2.80 2.82 2.67
75
TC
29.3 29.7 30.3 30.6 30.3 30.6 31.0 31.3 32.5 32.7 33.0 33.2 \ 39.7 39.8 39.9
S/T
0.99 1.00 1.00 1.00 0.63 0.88 1.00 1.00 0.39 0.59 0.78 1.00 \ 0.38 0.55 0.71
kW
2.26 2.28 2.32 2.32 2.32 2.34 2.36 2.39 2.39 2.41 2.43 2.46 \ 3.08 3.09 3.09
85
TC
28.7 29.0 29.7 30.0 29.7 30.0 30.3 30.6 31.8 32.0 32.3 32.4 \ 37.4 37.6 37.8
S/T
0.99 1.00 1.00 1.00 0.64 0.89 1.00 1.00 0.39 0.59 0.79 1.00 \ 0.39 0.56 0.73
kW
2.56 2.58 2.61 2.61 2.61 2.64 2.66 2.69 2.70 2.72 2.74 2.76 \ 3.29 3.32 3.34
95
TC
28.0 28.3 28.9 29.2 28.9 29.2 29.6 29.8 31.0 31.2 31.4 31.7 \ 35.6 35.7 35.7
S/T
1.00 1.00 1.00 1.00 0.64 0.90 1.00 1.00 0.39 0.60 0.80 1.00 \ 0.39 0.57 0.75
kW
3.00 3.04 3.07 3.07 3.07 3.10 3.13 3.16 3.18 3.20 3.22 3.24 \ 3.71 3.72 3.72
105
TC
27.2 27.5 28.1 28.4 28.1 28.4 28.7 29.0 30.2 30.3 30.5 30.8 \ 32.5 32.7 32.5
S/T
1.00 1.00 1.00 1.00 0.65 0.90 1.00 1.00 0.39 0.60 0.81 1.00 \ 0.39 0.59 0.79
kW
3.51 3.54 3.58 3.58 3.58 3.62 3.65 3.69 3.71 3.74 3.77 3.80 \ 3.90 3.92 3.86
115
TC
21.7 21.9 22.4 22.7 22.4 22.7 23.0 23.1 24.2 24.3 24.3 24.5 \ 25.9 26.0 26.1
S/T
1.00 1.00 1.00 1.00 0.66 1.00 1.00 1.00 0.40 0.66 0.93 1.00 \ 0.40 0.65 0.90
kW
3.10 3.13 3.17 3.17 3.17 3.20 3.23 3.27 3.31 3.32 3.34 3.35 \ 3.45 3.46 3.47
122
TC
18.5 18.6 19.1 19.3 19.1 19.3 19.5 19.7 20.5 20.6 20.7 20.8 \ 22.0 22.1 22.2
S/T
1.00 1.00 1.00 1.00 0.62 0.85 1.00 1.00 0.40 0.60 0.79 0.99 \ 0.39 0.58 0.76
kW
3.19 3.22 3.27 3.27 3.27 3.30 3.33 3.36 3.41 3.42 3.44 3.45 \ 3.56 3.57 3.58
70 80
75 5 8
70 80
75 5 8
70 80
75 5 8
Performance data (Heating operation at rated frequency)
36K outdoor unit matches 30K indoor unit
Airflow
(CFM)
ID
℉
OD
℉
75 65 55 47 35 25 15 5 -4 -13
800
60
TC 35.3 35.3 35.3 33.9 28.8 26.8 24.1 20.9 18.2 13.7
kW 2.09 2.23 2.63 2.86 2.66 2.84 2.68 2.54 2.42 1.94
70
TC 27.3 27.2 27.2 26.9 26.9 26.3 23.7 20.5 17.8 13.4
kW 1.56 1.65 1.94 2.26 2.71 3.09 2.90 2.73 2.58 2.06
75
TC 23.0 22.9 22.9 22.9 22.6 22.6 22.5 19.2 16.3 12.2
kW 1.30 1.40 1.63 1.93 2.24 2.63 3.03 2.85 2.68 2.14
80
TC 18.9 18.9 18.9 18.8 18.7 18.5 18.5 18.5 16.0 12.0
kW 1.08 1.15 1.35 1.57 1.87 2.11 2.45 2.89 2.80 2.24
1000
60
TC 39.5 39.5 38.4 34.3 29.2 27.2 24.6 21.3 18.5 13.9
kW 2.47 2.62 2.90 2.80 2.63 2.82 2.67 2.54 2.43 1.94
70
TC 30.6 30.4 30.2 30.0 28.5 26.6 24.3 20.8 18.1 13.6
kW 1.80 1.93 2.21 2.55 2.87 3.05 2.89 2.73 2.60 2.08
75
TC 25.8 25.7 25.7 25.3 25.3 25.3 22.8 19.5 16.6 12.5
kW 1.51 1.61 1.89 2.15 2.57 3.02 3.01 2.84 2.69 2.15
80
TC 21.1 21.1 21.1 21.0 20.8 20.7 20.8 19.2 16.3 12.2
kW 1.25 1.32 1.54 1.78 2.08 2.42 2.80 2.96 2.80 2.24
1200
60
TC 44.0 43.3 39.1 34.9 29.7 27.7 24.9 21.6 18.9 14.2
kW 2.90 2.97 2.89 2.80 2.65 2.84 2.71 2.59 2.48 1.98
70
TC 33.8 33.7 33.7 33.6 29.0 27.1 24.5 21.2 18.4 13.8
kW 2.07 2.20 2.59 3.01 2.88 3.07 2.91 2.78 2.66 2.13
75
TC 28.8 28.7 28.4 28.3 28.3 26.7 23.3 19.8 17.0 12.8
kW 1.76 1.87 2.13 2.49 2.96 3.20 3.04 2.89 2.75 2.20
80
TC 23.7 23.6 23.6 23.5 23.2 23.2 22.9 19.6 16.6 12.5
kW 1.47 1.55 1.78 2.08 2.41 2.79 3.16 3.00 2.85 2.28
SPECIFICATIONS
Capacities and Selection Data frequency