EasyManuals Logo

Froling P2-25 User Manual

Froling P2-25
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Operating the system
Heating up the boiler
Page 20
B0190806
s
3
Exchange the guide plate and replace
as shown
Put the steel cover onto the guide
plate
The combustion gases path over
the guide plates is blocked.
2.
Hang 2 chamber guards each on the
left and right in the combustion
chamber on the bolts provided
3.
Insert the grate
It sits on the angled edges of the
combustion chamber guards.
4.
3.4.2 Filling the combustion chamber with firewood
Place a layer of firewood broken into small pieces on the grate
Place paper, cardboard or similar on top
Fill the rest of the space with firewood
3.4.3 Setting the controls
For emergency firewood operation, the mode must be set to “Firewood
operation on the controls:
Press the key
ENTER
The arrow on the display
points to “Set”
Press the key
ENTER
Press the key until the arrow
points to mode
For example, winter
operation.
Mode
Winter operation
Set
Error display

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling P2-25 and is the answer not in the manual?

Froling P2-25 Specifications

General IconGeneral
BrandFroling
ModelP2-25
CategoryBoiler
LanguageEnglish

Related product manuals