EasyManuals Logo

Froling P2-25 User Manual

Froling P2-25
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
Installers and service technicians
Initial startup
Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestraße 12, A-4710 Grieskirchen, Austria Page 61
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com
B0190806
7
System
This table shows the variants, which are currently possible with the
Lambdatronic 3100. There is a more detailed description in the Fröling
energy system brochure.
Permanently available Options
Storage tank
DHW tank
Oil boiler
Return feed mixer
Hot water HE
Solar HE
2 DHW tanks
Bypass pump
DHW tank
Burner blocking
Oil switch valve
Filler storage middle
DHW tank priority
HC1
HC2
HC3
HC4
Solar element
System 0 x x x x x x x x
System 1 x x x x x x x x
System 2 x x x x x x x x x x
System 3 x x
x x x x x x x
System 4 x x x x x x x x x
System 5 x x x x x x x x x x x x
System 6 x x x
x x x x x x x x x
System 8 x
x x x x x x
System 9 x x
x x x x x x x
System 10 x x x x x x x
System 12 x x x x x x x
System 13 x x x x x x x x
System 14 x x x x x x x
System 15 x x x x x x x x
x ... without solar element