Untrained operators may enter incorrect settings!
Incorrectly set parameters at “Installer” and “Service” level can
cause serious problems with boiler functioning!
7.4.3 Setting system type
Boiler types and parameters
FHG … FHG … do not select, position the arrow on one of the other types.
P2 – 10 …X←
←←
← Lambda probe
available N ←
←←
←
Y, if a Lambda probe is available.
P2 – 15 … Boilerlaunch in av N ←
←←
← See page 35, “10.10 Boiler release”
P2 – 20 …
Boiler off when
no heat required N ←
←←
←
Automatic operation of the system in transitional or
winter operation. The boiler is started when required by a
heating circuit or by the DHW tank
P2 – 25 … Supply bin N←
←←
← Y, if the system is manually fed with a supply bin
Screw discharge N←
←←
←
Y, if chamber discharge is carried out by direct screw
discharge.
Suction screw
discharge N ←
←←
←
Y, if chamber discharge is carried out by direct screw
discharge.
Manual univ.
suction system N←
←←
←
Y, if chamber discharge is carried out by manual universal
suction system.
Automatic univ.
suction system N←
←←
←
Y, if chamber discharge is carried out by automatic
universal suction system.
Clean
Y ←
←←
←
Daily cleaning of combustion bowl
MANUAL ANAL. OUT
SYSTEM SELECTION