Adress Description Read Write Group Unit Type Factor
E0AF Hourmeter total high-word True False Generic Min Word 0,1
E0B0 Write 0x78E3 for factory- False True Generic Integer 1
comand-unlock
E0B1 Write 0x56AA for factory- False True Generic Integer 1
comand, unlock and command
have to set at the same
message
E0B2 Result of factory-command True False Generic Integer 1
0 Factory-command never
started
1 OK
2 unlock was written,
but no command
3 unlock OK, but command
not
4 unlock was wrong
E0B3 Write 0x65F7 for RL-adjust- False True Generic Integer 1
command-unlock
E0B4 Write 0x3FEA for RL-adjust- False True Generic Integer 1
command, unlock and command
have to set at the same message
E0B5 Result of RL-adjustment- True False Generic Integer 1
command
0 RL-adjustment-command
never started
1 OK
2 unlock was written,
but no command
3 unlock OK, but command
not
4 unlock was wrong
5 test is running
6 command cannot be
started
E0B6 RL-adjust error True False Generic Integer 1
E0B7 Write 0x7BC3 for PPU-adjust- False True Generic Integer 1
command-unlock
E0B8 Write for PPU-adjust- False True Generic Integer 1
command, unlock and command
have to be in the same message
Bit[7....0] Testnumber
Valid are 0 = Test1
1 = Test2
Bit8 0 = Stop Test
1 = Start Test
E0B9 Result of PPU-adjust- True False Generic Integer 1
command
0 PPU-adjustment-
command never started
1 OK
2 unlock was written,
but no command
3 unlock OK, but command
not
4 unlock was wrong
5 test is running
6 command cannot be
started