AB Profinet signal description
General Depending on the selected mode, the AB Profinet interface can transfer numerous kinds
of input and output signals.
Power source
operating modes
Operating mode E05 E04 E03
Standard program 0 0 0
Pulsed arc program 0 0 1
Job mode 0 1 0
Internal parameter selection 0 1 1
Manual 1 0 0
CC/CV 1 0 1
TIG 1 1 0
HAP 1 1 0
CMT/special process 1 1 1
Overview "AB Profinet signal description" is composed of the following sections:
- Input and output signals for MIG/MAG standard/pulse synergic and CMT
- Input and output signals for TIG
- Input and output signals for HAP
- Input and output signals for CC/CV
- Input and output signals for standard manual
67