Data transfer properties and technical data
Data transfer pro-
perties
Transmission technology Ethernet
Network topology Star
Medium Twisted pair cable
Transmission rate 100 Mbit/s, full duplex mode
Bus connection
AB Profinet RT
AB Profinet IRT
AB Profinet IRT FO
Ethernet RJ 45 Harting
Ethernet RJ 45 VarioSub
SCRJ-MM-C V14
Process data width 296 bits (standard configuration)
Process data format Intel
Safety features If there is no data transfer, all inputs and outputs are reset and the power source goes
into "Stop" mode. Once data transfer has been re-established, the following signals
resume the process:
- "Robot ready" signal
- "Source error reset" signal
AB Profinet tech-
nical data
Power supply internal
Installation position on the rear of the power sources
I/O Input max. 512 bytes
I/O output max. 512 bytes
Degree of protection IP 23
Configuration interface via field bus configuration module
Device master
file
A device master file is assigned to every node in a Profinet network.
The device master file contains all the information about the node. It is required for net-
work configuration and can be downloaded from the following website:
http://www.anybus.de/products/profi net/Techn. Dokumentation/GSDML-V1.0-Hms-
ABSPRT