EasyManua.ls Logo

Fronius AB Profinet RT - Input and Output Signals for MIG;MAG Standard Pulse Synergic and CMT

Fronius AB Profinet RT
216 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input and output signals for MIG/MAG standard
pulse synergic and CMT
Input signals
(from robot to
power source)
Seq. no. Signal designation Range Activity
E01 Welding start - High
E02 Robot ready - High
E03 Modes Bit 0 - High
E04 Modes Bit 1 - High
E05 Modes Bit 2 - High
E06 Master selection twin - High
E07 Not in use - -
E08 Not in use - -
E09 Gas Test - High
E10 Wire feed - High
E11 Wire retract - High
E12 Source error reset - High
E13 TouchSensing - High
E14 Welding torch blow out - High
E15 Not in use - -
E16 Not in use - -
E17 - E24 Job number 0 - 99 -
E25 - E31 Program number 0 - 127 -
E32 Welding simulation - High
With RCU 5000i remote control unit and in Job mode
E17 - E31 Job number 0 - 999
E32 Welding simulation - High
Power (set value) 0 - 65535
(0% - 100%)
-
E33 - E40 Low Byte - -
E41 - E48 High Byte - -
Arc length correction (set value) 0 - 65535
(-30% - +30%)
-
E49 - E56 Low Byte - -
E57 - E64 High Byte - -
68