Adress Description Read Write Group Unit Type Factor
E000 Main error True False Generic Word 1
E001 Sub error True False Generic Word 1
E002 Status Flag True False Generic Word 1
Bit 0 maincurrent
Bit 1 cooler
Bit 2 fan1
Bit 3 gas1
Bit 4 coolersensor
Bit 5 processrun
Bit 6 processact
Bit 7 wf started
Bit 8 weldstart
Bit 9 inching
Bit 10 gastest
Bit 11 keylock
Bit 12 UST-fan
Bit 13 currentfl ow
Bit 14 started up
Bit 15 hold
E003 Status Flag True False Generic Word 1
Bit 0 1=DC+ enable
Bit 1 1=Needle OVL
Bit 2 1=3 phase machine
Bit 3 1=Magic Wave
Bit 4 1=TIG / HAP
Bit 5 1=I-RV-display
Bit 6 1=U-RV-display
Bit 7 1=Fd-RV-display
Bit 8 1=enable jobchange
Bit 9 1=par.-select.-int.
Bit 10 1=Touchsensing active
E004 Reserved True False Generic Word 1
E005 Jobnumber True True Generic Word 1
E007 Push pull unit [PPU] True True Generic Word 1
E008 Opterating mode True True Generic Word 1
0 MIG Standard
1 MIG Pulse
2 Stick
3 TIG / HAP
4 Job mode
5 Manual mode
6 CC/CV
7 CMT special mode
8 Unused
9 Manual standard
10 Manual puls
255 Invalid
E009 Coolerfl ow True False Generic l/min Word 0,001
E00A Cooler fi ltertime [C-t] True True Generic s Word 1
E078 Powermaster-setting [P-C] True True Generic Boolean 1
E0A2 Key lock True True Generic Word 1
0 unlocked
1 locked
E0AC Hourmeter currentfl ow low-word True False Generic Min Word 0,1
E0AD Hourmeter currentfl ow high-word True False Generic Min Word 0,1
E0AE Hourmeter total low-word True False Generic Min Word 0,1