EasyManua.ls Logo

Fronius AB Profinet RT - Page 75

Fronius AB Profinet RT
216 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Input and output signals for TIG
Input signals
(from robot to
power source)
Seq. no. Signal designation Range Activity
E01 Welding start - High
E02 Robot ready - High
E03 Modes Bit 0 - High
E04 Modes Bit 1 - High
E05 Modes Bit 2 - High
E06 Not in use - -
E07 Not in use - -
E08 Not in use - -
E09 Gas Test - High
E10 Wire feed - High
E11 Wire retract - High
E12 Source error reset - High
E13 TouchSensing - High
E14 Cold wire disable - High
E15 Not in use - -
E16 Not in use - -
E17 - E24 Job number 0 - 99 -
E25 DC/AC - High
E26 DC- / DC + - High
E27 Cap-shaping - High
E28 Pulse disable - High
E29 Pulse range bit 0 - High
E30 Pulse range bit 1 - High
E31 Pulse range bit 2 - High
E32 Welding simulation - High
Main current (set value) 0 - 65535
(0 - I
max
)
-
E33 - E40 Low Byte - -
E41 - E48 High Byte - -
75
EN

Table of Contents