Input and output signals for HAP
HAP input
signals (from
robot to power
source)
Power source input data in the HAP (Hot Active Plasma) process image
Seq. no. Signal designation Range Activity
E01 Process start - High
E02 Robot ready - High
E03 Modes Bit 0 - High
E04 Modes Bit 1 - High
E05 Modes Bit 2 - High
E06 Not in use - -
E07 Not in use - -
E08 Not in use - -
E09 Gas Test - High
E10 Not in use - -
E11 Not in use - -
E12 Source error reset - High
E13 Not in use - -
E14 Not in use - -
E15 Not in use - -
E16 Not in use - -
E17 - E24 Job number 0 - 99 -
E25 Not in use - -
E26 Not in use - -
E27 Not in use - -
E28 Pulse disable - High
E29 Pulse range bit 0 - High
E30 Pulse range bit 1 - High
E31 Pulse range bit 2 - High
E32 Process simulation - High
Main current (set value) 0 - 65535 (0 - max.) -
E33 - E40 Low Byte - -
E41 - E48 High Byte - -
External parameter (set value) 0 - 65535 -
E49 - E56 Low Byte - -