Output signals
(from power
source to robot)
Seq. no. Signal designation Range Activity
A01 Arc stable - High
A02 Not in use - -
A03 Process active - High
A04 Main current signal - High
A05 Welding torch collision protection - High
A06 Power source ready - High
A07 Communication ready - High
A08 Life Cycle Toggle Bit Every 250 ms -
A09 - A16 Error number - High
A17 - A24 Not in use - -
A25 Not in use - -
A26 High frequency active - High
A27 Not in use - -
A28 Not in use - -
A29 Not in use - -
A30 Not in use - -
A31 Pulse high - High
A32 Not in use - -
Process voltage actual value 0 - 65535 (0 - 100 V) -
A33 - A40 High Byte - -
A41 - A48 Low Byte - -
Process current actual value 0 - 65535 (0 - 1000 A) -
A49 - A56 High Byte - -
A57 - A64 Low Byte - -
A65 - A72 Not in use - -
A73 - A80 Not in use - -
A81 - A88 Arc length actual value (AVC) 0 - 255 (0 - 50 V) -
A89 - A96 Not in use - -
A97 -
A104
Not in use - -