© FRONIUS 2013 38
23. Usage
1.15 Saving a program
The controller allows you to define up to 9 welding programs.
The single program contains the values of the following parameters:
Travel speed (knob B)
Oscillation amplitude (E)
Oscillation speed (F)
Left oscillation dwell time (G)
Middle oscillation dwell time (H)
Right oscillation dwell time (I)
Crater filling (K)
Rotate a proper knob right to increase the value of a parameter and rotate it left
to decrease the value. Once set, the value of the parameter is shown on the
display for a while. Pressing the knob shows the set value.
Saving the current parameters to memory:
Set the travel direction switch A to neutral position
Set the limit switch function switch J to lower position
Simultaneously press and hold the travel speed adjustment knob B and the
crater fill K knobs for 4 seconds
A notice “memX” will appear on the display. “X” means the number of the
program to save the current parameters to.
Rotate the travel speed knob B to change the number and press the knob to
apply the choice.