34
No. Function
(1) Level sensor
monitors the parting agent fill level in the dipping bowl
(2) Cleaning opening with internal parting-agent injection nozzle and brush seal
for cleaning the gas nozzle and the inside of the welding torch
for coating the gas nozzle and welding torch interior with parting agent
NOTE!
To avoid excess soiling, only use the device with the brush seal in place.
(3) Dipping bowl with spill tray
NOTE!
If the dipping bowl is not in use, ensure that there are no parting agent residues left 
in the bottom.
NOTE!
Ensure that there is always sufficient parting agent in the dipping bowl when in use 
(i.
e., ensure that the fill level indicator never lights up).
(4) Standard I/O connection socket (X1)
(5) Mains cable with strain relief device (mains cable not provided with Robacta 
TC 2000 US)
(6) Spatter tray for welding residues (in optional installation stand)
(7) Recesses for the wire cutter holder
for attaching the wire cutter holder to the cleaning device
(8) Drain hose
for emptying the dipping bowl
(9) Parting agent nebuliser connection
for connecting to the "Robacta Reamer" parting agent container, for spraying the 
compressed air/parting agent mixture into the cleaning opening
(10) Wire cutter connection socket
for electrically controlling the wire cutter
(11) Compressed air connection
for supplying the cleaning device with compressed air