Before commissioning
Operators, main-
tenance person-
nel
NOTE!
The device must only be used by one person at a time.
It is also necessary to ensure that no one else is within the working area of the device when
the device is being used.
NOTE!
The device must only be serviced by one person at a time.
It is also necessary to ensure that no one else is within the working area of the device when
the device is being serviced.
Setup regulations The device is tested to IP 21, meaning:
- protection against penetration by solid foreign bodies with diameters > 12.5 mm (0.49
in.)
- protection against vertically falling drops of water
The device must not be set up and operated outdoors. The built in electrical parts must be
protected from direct wetting.
NOTE!
The device must be set up at least 1 m (40 in.
) away from computers, control lines and the welding process.
NOTE!
When setting up the device, ensure an all-round clearance of at least 0.
5 m (19.69 in.) from any surrounding objects, e.g. walls, other devices or objects.
NOTE!
Position the device to prevent welding spatter coming into contact with the cleaning
device.
Compressed air
supply specifica-
tions
To ensure that the cleaning device functions correctly, the following compressed air supply
specifications must be met:
- Establish compressed air supply using a pressure limiter and compressed air filter
- Provide compressed air quality conforming to ISO 8573-1:2001, class 7 4 3, instru-
ment air
- Solid particle concentration 10 mg/m
3
- Vapour pressure dew point + 3°C
- Oil concentration 1 mg/m
3